OpenTherm.h - OpenTherm Library for the ESP8266/Arduino platform
|
||
https://github.com/ihormelnyk/OpenTherm
|
||
http://ihormelnyk.com/pages/OpenTherm
|
||
Licensed under MIT license
|
||
Copyright 2018, Ihor Melnyk
|
||
|
||
Frame Structure:
|
||
P MGS-TYPE SPARE DATA-ID DATA-VALUE
|
||
0 000 0000 00000000 00000000 00000000
|
||
*/
|
||
|
||
#ifndef OpenTherm_h
|
||
#define OpenTherm_h
|
||
|
||
#include <stdint.h>
|
||
#include <Arduino.h>
|
||
|
||
enum OpenThermResponseStatus : uint8_t
|
||
{
|
||
NONE,
|
||
SUCCESS,
|
||
INVALID,
|
||
TIMEOUT
|
||
};
|
||
|
||
enum OpenThermMessageType : uint8_t
|
||
{
|
||
/* Master to Slave */
|
||
READ_DATA = B000,
|
||
READ = READ_DATA, // for backwared compatibility
|
||
WRITE_DATA = B001,
|
||
WRITE = WRITE_DATA, // for backwared compatibility
|
||
INVALID_DATA = B010,
|
||
RESERVED = B011,
|
||
/* Slave to Master */
|
||
READ_ACK = B100,
|
||
WRITE_ACK = B101,
|
||
DATA_INVALID = B110,
|
||
UNKNOWN_DATA_ID = B111
|
||
};
|
||
|
||
typedef OpenThermMessageType OpenThermRequestType; // for backwared compatibility
|
||
|
||
enum OpenThermMessageID : uint8_t
|
||
{
|
||
Status, // flag8 / flag8 Master and Slave Status flags.
|
||
TSet, // f8.8 Control setpoint ie CH water temperature setpoint (°C)
|
||
MConfigMMemberIDcode, // flag8 / u8 Master Configuration Flags / Master MemberID Code
|
||
SConfigSMemberIDcode, // flag8 / u8 Slave Configuration Flags / Slave MemberID Code
|
||
Command, // u8 / u8 Remote Command
|
||
ASFflags, // / OEM-fault-code flag8 / u8 Application-specific fault flags and OEM fault code
|
||
RBPflags, // flag8 / flag8 Remote boiler parameter transfer-enable & read/write flags
|
||
CoolingControl, // f8.8 Cooling control signal (%)
|
||
TsetCH2, // f8.8 Control setpoint for 2e CH circuit (°C)
|
||
TrOverride, // f8.8 Remote override room setpoint
|
||
TSP, // u8 / u8 Number of Transparent-Slave-Parameters supported by slave
|
||
TSPindexTSPvalue, // u8 / u8 Index number / Value of referred-to transparent slave parameter.
|
||
FHBsize, // u8 / u8 Size of Fault-History-Buffer supported by slave
|
||
FHBindexFHBvalue, // u8 / u8 Index number / Value of referred-to fault-history buffer entry.
|
||
MaxRelModLevelSetting, // f8.8 Maximum relative modulation level setting (%)
|
||
MaxCapacityMinModLevel, // u8 / u8 Maximum boiler capacity (kW) / Minimum boiler modulation level(%)
|
||
TrSet, // f8.8 Room Setpoint (°C)
|
||
RelModLevel, // f8.8 Relative Modulation Level (%)
|
||
CHPressure, // f8.8 Water pressure in CH circuit (bar)
|
||
DHWFlowRate, // f8.8 Water flow rate in DHW circuit. (litres/minute)
|
||
DayTime, // special / u8 Day of Week and Time of Day
|
||
Date, // u8 / u8 Calendar date
|
||
Year, // u16 Calendar year
|
||
TrSetCH2, // f8.8 Room Setpoint for 2nd CH circuit (°C)
|
||
Tr, // f8.8 Room temperature (°C)
|
||
Tboiler, // f8.8 Boiler flow water temperature (°C)
|
||
Tdhw, // f8.8 DHW temperature (°C)
|
||
Toutside, // f8.8 Outside temperature (°C)
|
||
Tret, // f8.8 Return water temperature (°C)
|
||
Tstorage, // f8.8 Solar storage temperature (°C)
|
||
Tcollector, // f8.8 Solar collector temperature (°C)
|
||
TflowCH2, // f8.8 Flow water temperature CH2 circuit (°C)
|
||
Tdhw2, // f8.8 Domestic hot water temperature 2 (°C)
|
||
Texhaust, // s16 Boiler exhaust temperature (°C)
|
||
TheatExchanger, // f8.8 Boiler heat exchanger temperature (°C)
|
||
BoilerFanSpeed, // u16 Boiler fan speed Setpiont and actual value
|
||
ElectricBurnerFlame, // f8.8?? Electric current through burner flame (mюA)
|
||
TdhwSetUBTdhwSetLB = 48, // s8 / s8 DHW setpoint upper & lower bounds for adjustment (°C)
|
||
MaxTSetUBMaxTSetLB, // s8 / s8 Max CH water setpoint upper & lower bounds for adjustment (°C)
|
||
HcratioUBHcratioLB, // s8 / s8 OTC heat curve ratio upper & lower bounds for adjustment
|
||
TdhwSet = 56, // f8.8 DHW setpoint (°C) (Remote parameter 1)
|
||
MaxTSet, // f8.8 Max CH water setpoint (°C) (Remote parameters 2)
|
||
Hcratio, // f8.8 OTC heat curve ratio (°C) (Remote parameter 3)
|
||
RemoteOverrideFunction = 100, // flag8 / - Function of manual and program changes in master and remote room setpoint.
|
||
OEMDiagnosticCode = 115, // u16 OEM-specific diagnostic/service code
|
||
BurnerStarts, // u16 Number of starts burner
|
||
CHPumpStarts, // u16 Number of starts CH pump
|
||
DHWPumpValveStarts, // u16 Number of starts DHW pump/valve
|
||
DHWBurnerStarts, // u16 Number of starts burner during DHW mode
|
||
BurnerOperationHours, // u16 Number of hours that burner is in operation (i.e. flame on)
|
||
CHPumpOperationHours, // u16 Number of hours that CH pump has been running
|
||
DHWPumpValveOperationHours, // u16 Number of hours that DHW pump has been running or DHW valve has been opened
|
||
DHWBurnerOperationHours, // u16 Number of hours that burner is in operation during DHW mode
|
||
OpenThermVersionMaster, // f8.8 The implemented version of the OpenTherm Protocol Specification in the master.
|
||
OpenThermVersionSlave, // f8.8 The implemented version of the OpenTherm Protocol Specification in the slave.
|
||
MasterVersion, // u8 / u8 Master product version number and type
|
||
SlaveVersion, // u8 / u8 Slave product version number and type
|
||
};
|
||
|
||
enum OpenThermStatus : uint8_t
|
||
{
|
||
NOT_INITIALIZED,
|
||
READY,
|
||
DELAY,
|
||
REQUEST_SENDING,
|
||
RESPONSE_WAITING,
|
||
RESPONSE_START_BIT,
|
||
RESPONSE_RECEIVING,
|
||
RESPONSE_READY,
|
||
RESPONSE_INVALID
|
||
};
|
||
|
||
class OpenTherm
|
||
{
|
||
public:
|
||
OpenTherm(int inPin = 4, int outPin = 5, bool isSlave = false);
|
||
volatile OpenThermStatus status;
|
||
void begin(void (*handleInterruptCallback)(void));
|
||
void begin(void (*handleInterruptCallback)(void), void (*processResponseCallback)(unsigned long, OpenThermResponseStatus));
|
||
bool isReady();
|
||
unsigned long sendRequest(unsigned long request);
|
||
bool sendResponse(unsigned long request);
|
||
bool sendRequestAync(unsigned long request);
|
||
unsigned long buildRequest(OpenThermMessageType type, OpenThermMessageID id, unsigned int data);
|
||
unsigned long buildRequestID(OpenThermMessageType type, unsigned int id, unsigned int data);
|
||
unsigned long buildResponse(OpenThermMessageType type, OpenThermMessageID id, unsigned int data);
|
||
unsigned long getLastResponse();
|
||
OpenThermResponseStatus getLastResponseStatus();
|
||
const char *statusToString(OpenThermResponseStatus status);
|
||
void handleInterrupt();
|
||
void process();
|
||
void end();
|
||
|
||
bool parity(unsigned long frame);
|
||
OpenThermMessageType getMessageType(unsigned long message);
|
||
OpenThermMessageID getDataID(unsigned long frame);
|
||
const char *messageTypeToString(OpenThermMessageType message_type);
|
||
bool isValidRequest(unsigned long request);
|
||
bool isValidResponse(unsigned long response);
|
||
|
||
// requests
|
||
unsigned long buildSetBoilerStatusRequest(bool enableCentralHeating, bool enableHotWater = false, bool enableCooling = false, bool enableOutsideTemperatureCompensation = false, bool enableCentralHeating2 = false, bool enableSummerMode = false, bool dhwBlock = false);
|
||
unsigned long buildSetBoilerTemperatureRequest(float temperature);
|
||
unsigned long buildGetBoilerTemperatureRequest();
|
||
|
||
// responses
|
||
bool isFault(unsigned long response);
|
||
bool isCentralHeatingActive(unsigned long response);
|
||
bool isHotWaterActive(unsigned long response);
|
||
bool isFlameOn(unsigned long response);
|
||
bool isCoolingActive(unsigned long response);
|
||
bool isDiagnostic(unsigned long response);
|
||
uint16_t getUInt(const unsigned long response) const;
|
||
float getFloat(const unsigned long response) const;
|
||
unsigned int temperatureToData(float temperature);
|
||
|
||
// basic requests
|
||
unsigned long setBoilerStatus(bool enableCentralHeating, bool enableHotWater = false, bool enableCooling = false, bool enableOutsideTemperatureCompensation = false, bool enableCentralHeating2 = false, bool enableSummerMode = false, bool dhwBlock = false);
|
||
bool setBoilerTemperature(float temperature);
|
||
float getBoilerTemperature();
|
||
float getReturnTemperature();
|
||
bool setDHWSetpoint(float temperature);
|
||
float getDHWTemperature();
|
||
float getModulation();
|
||
float getPressure();
|
||
unsigned char getFault();
|
||
|
||
//Имитация ответов от котла, TRUE - идет имитация ответов котла, в котел так же шлется (лучше его отключить), FALSE - штатная работа
|
||
void imitation(bool fl) {imitFlag = fl;}
|
||
|
||
private:
|
||
bool imitFlag;
|
||
void ImitationResponse(unsigned long request);
|
||
|
||
const int inPin;
|
||
const int outPin;
|
||
const bool isSlave;
|
||
|
||
volatile unsigned long response;
|
||
volatile OpenThermResponseStatus responseStatus;
|
||
volatile unsigned long responseTimestamp;
|
||
volatile byte responseBitIndex;
|
||
|
||
int readState();
|
||
void setActiveState();
|
||
void setIdleState();
|
||
void activateBoiler();
|
||
|
||
void sendBit(bool high);
|
||
void (*handleInterruptCallback)();
|
||
void (*processResponseCallback)(unsigned long, OpenThermResponseStatus);
|
||
};
|
||
|
||
#ifndef ICACHE_RAM_ATTR
|
||
#define ICACHE_RAM_ATTR
|
||
#endif
|
||
|
||
#ifndef IRAM_ATTR
|
||
#define IRAM_ATTR ICACHE_RAM_ATTR
|
||
#endif
|
||
|
||
#endif // OpenTherm_h
|